Sallen-Key Anti-Alias
6 parts
Second-order low-pass filter built with one op-amp: used everywhere in front of ADC for cleaning a signal before you measure it
- V1 2V·300Hz
- R1 1.6kΩ
- R2 1.6kΩ
- C1 100nF
- OP1
- C2 100nF
6 parts
Second-order low-pass filter built with one op-amp: used everywhere in front of ADC for cleaning a signal before you measure it