Open-wire detection on a battery sense line
8 parts
A test sink pulls a cell's sense line once a second; with the wire intact the reading dips only 10mV. Click the sense wire open: the next full test drains the reading to 0.2V. The cell (3.3V) reaches the chip's pin, tap, through the sense wire (a live switch), Rf 100Ω and Cf 3.3µF to ground. The test sink is Rsink, 33kΩ, switched by test, a voltage-controlled switch the test clock closes for 0.3s each second: about 100µA. Press Run: on screen at ×0.25 a test comes every 1.6s. Click the sense wire (its label reads closed) between tests: nothing changes, as Cf holds the reading, until the next test drains it. Click again: the reading is back at once.
- Rsink 33kΩ
- cell 3.3V
- sense wire closed
- Rf 100Ω
- Cf 3.3µF
- test ≥2.5V
- test clock 5V·1Hz