Cell Voltage Sense Filter mismatch under load step

by VladM

13 parts

Two battery cell taps reach the measuring chip through RC filters, one 20% slower. Watch a 100A load step: the real cell drops 0.1V, but the reading first rises 48mV. Cells 1–15 (49.5V and 15mΩ, as one source) sit under cell 16 (3.3V, 1mΩ). Each tap reaches the chip through 10kΩ and a capacitor to ground: Cf15 10µF, Cf16 12µF. The load, an I source, steps from 0 to 100A at 0.25s; its label shows 100A from the start. Under load every tap falls by the drop of all the cells beneath it, tap 16 by 1.6V and tap 15 by 1.5V, while the cell itself falls 0.1V. Matched filters would only delay that; here the slower top filter lags, and the difference swings up first. Press Run: on screen at ×0.25 the step comes at about 2s and the error peaks at about 2.5s. The panels show the error, the true cell (tap16 − tap15) and the reading (in16 − in15).